Arterial Switch Operation with Unidirectional Valved Patch Closure of Ventricular Septal Defect in Patients with Transposition of Great Arteries and Severe Pulmonary Hypertension
Between July 2009 and February 2011, six patients with TGAs, VSD, and severe PAH (mean age 39.8 ± 47.4 months, median 21, range 8-132 months), weighing 10.7 ± 9.2 kg (median 8.6, range 4.3-29 kg), underwent ASO with VSD closure using our simple technique of UVP. Mean pulmonary artery systolic pressure before the operation was 106 ± 12.7 mm Hg (median 107.5, range 95-126 mm Hg) and pulmonary vascular resistance was 9.5 ± 4.22 units (median 9.5, range 6.6-17.1 Wood units). There were no deaths. All patients had a postoperative systemic arterial saturation of more than 95%, although there were frequent episodes of systemic desaturation due to right-to-left shunt across the valved VSD patch (as seen on transesophageal and transthoracic echocardiograms). At most recent follow-up, all patients had systemic arterial saturation of more than 95% and no right-to-left shunt through the VSD patch. Arterial switch operation with UVP VSD closure is feasible with acceptable early results. It avoids complications of palliative atrial switch (arrhythmia and baffle obstruction) and partially or completely open VSD.